System status LEDs
3
8 Brocade Mobility RFS4000 Controller Installation Guide
53-1001933-02
Start up / POST (primary system or redundant system)
NOTE
During controller start up, the Temperature status LED will be lit Solid Amber. This is
normal behavior and does not indicate an error. At the completion of start up the
Temperature Status LED will controller to Solid Green.
Controller status (primary system)
System status 1 LED System status 2 LED Event
off off power off
green blinking green blinking power on self test (POST)
running
green solid green blinking post succeeded (operating
system loading)
green solid off post succeeded (normal
operation)
amber blinking off post failure
alternating green blinking &
amber blinking
alternating green blinking &
amber blinking
system boot up error
System status 1
LED
System status 2
LED
Event
off off power off
green solid off redundancy feature enabled
primary system normal operation no access ports
adopted
green solid green solid redundancy feature enabled
primary system normal operation actively adopting
access ports
green solid amber blinking no country code configured on the controller or access
port or adaptive ap license and country code configured,
but no aps adopted
MobilityRFS4000ControllerInstallGuide.book Page 8 Friday, June 10, 2011 1:32 PM