Brocade Communications Systems Encryption Switch Servisní příručka Strana 1

Procházejte online nebo si stáhněte Servisní příručka pro Síťové přepínače Brocade Communications Systems Encryption Switch. Brocade Communications Systems Encryption Switch Technical data Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk

Shrnutí obsahu

Strany 1 - Brocade Encryption Switch

53-1001118-0118 August 2008 53-1001118-01*53-1001118-01*18 August 2008Brocade Encryption SwitchQuickStart GuideSupporting Fabric OS v6.1.1_enc

Strany 2 - Document History

10 of 20 Encryption Switch QuickStart Guide53-1001118-01Items included with the switchThe following items are included with the standard shipment of t

Strany 3 - Overview

Encryption Switch QuickStart Guide 11 of 2053-1001118-01Configuring the switchTo configure the switch, perform the following tasks. Figure 6 illustrat

Strany 4 - Port side of the switch

12 of 20 Encryption Switch QuickStart Guide53-1001118-01FIGURE 6 Switch configuration

Strany 5 - Non-port side of the switch

Encryption Switch QuickStart Guide 13 of 2053-1001118-01Connecting a serial cable between switch and hostFollow these steps to connect a serial cable.

Strany 6 - FIGURE 4 Power supply

14 of 20 Encryption Switch QuickStart Guide53-1001118-01Setting the IP addressConfigure the switch with a static IP address.Setting a static IP addres

Strany 7 - FIGURE 5 Fan assembly

Encryption Switch QuickStart Guide 15 of 2053-1001118-01Setting the domain IDTo set the switch domain ID, follow these steps.1. Log on to the switch b

Strany 8 - Time and items required

16 of 20 Encryption Switch QuickStart Guide53-1001118-01switch:admin> dateFri Sep 26 17:01:48 UTC 2008switch:admin> date "0926123008"F

Strany 9 - ATTENTION

Encryption Switch QuickStart Guide 17 of 2053-1001118-01switch:admin> tsclockserverLOCLswitch:admin> tsclockserver "132.163.135.131" s

Strany 10 - Powering on the switch

18 of 20 Encryption Switch QuickStart Guide53-1001118-01NOTEEach SFP has a 10-pad gold-plated PCB-edge connector on the bottom. The correct position t

Strany 11 - Configuring the switch

Encryption Switch QuickStart Guide 19 of 2053-1001118-01Managing cablesATTENTIONThe minimum bend radius for a 50 micron cable is 2 in. under full tens

Strany 12 - FIGURE 6 Switch configuration

2 of 20 Encryption Switch QuickStart Guide53-1001118-01Copyright © 2008 Brocade Communications Systems, Inc. All Rights Reserved.Brocade, the Brocade

Strany 13 - • In a Windows environment:

20 of 20 Encryption Switch QuickStart Guide53-1001118-01After completing the pre-initialization tasks, you may need to perform several tasks related t

Strany 14 - Setting the IP address

Encryption Switch QuickStart Guide 3 of 2053-1001118-01OverviewThis QuickStart guide is intended as an overview to help experienced installers unpack,

Strany 15 - Setting the date and time

4 of 20 Encryption Switch QuickStart Guide53-1001118-01Port side of the switchThe port side of the switch (Figure 1) includes the switch power and sta

Strany 16 - Setting the time zone

Encryption Switch QuickStart Guide 5 of 2053-1001118-01Port NumberingThe Fibre Channel ports on the switch are numbered from 0 to 31 (Figure 2).FIGURE

Strany 17 - 53-1001118-01

6 of 20 Encryption Switch QuickStart Guide53-1001118-01Field-replaceable units (FRUs)The switch has two power supply (Figure 4) and three fan assembly

Strany 18

Encryption Switch QuickStart Guide 7 of 2053-1001118-01FIGURE 5 Fan assembly1Captive screw2 Fan status LED

Strany 19 - Configuring for encryption

8 of 20 Encryption Switch QuickStart Guide53-1001118-01Time and items requiredYou can set up and install the Brocade Encryption Switch in the followin

Strany 20 - Encryption configuration

Encryption Switch QuickStart Guide 9 of 2053-1001118-01Site preparation and installation guidelinesThe following steps are required to ensure correct

Komentáře k této Příručce

Žádné komentáře