Brocade MLX Series and NetIron XMR Hardware Installation Guide 287
53-1003267-02
Replacing fan assemblies
7
Replacing the air filter in Brocade MLX and NetIron XMR 4-slot and 8-slot routers
Follow these steps to replace the air filter in 4-slot and 8-slot routers.
1. Loosen the two screws in the front of the filter retainer.
2. Pull the filter retainer away from the router as shown in Figure 165 or Figure 166.
FIGURE 165 Air filter removal and replacement for a Brocade MLX or NetIron XMR 4-slot router.
FIGURE 166 Air filter removal and replacement for the 8-slot router.
3. Pull the old air filter out of the router and discard it.
4. Insert the replacement air filter by sliding it along the metal guides.
1 Direction of airflow in device 3 Filter retainer
2Filter 4Fan trap
1 Direction of airflow in device 3 Filter retainer
2Filter 4Fan trap